DFR Fingertip: Delay-Line Transducers


 
Model DFR are small-diameter delay-line transducers with side-mounted microdot connectors. Removable delay lines and highly damped piezoceramic elements enable measurement of very thin parts or detection of small near-surface flaws. Delay lines can be contoured for improved coupling to I.D. or O.D. curved parts. DFRs are available in HR Series* which are specialized applications requiring high resolution. Custom sizes and shapes also available upon request.
 
Delay-line contacts are single-element, longitudinal-wave (straight beam) transducers designed for detection of near-surface flaws and thickness measurement of thin-section materials. Replaceable delay lines (stand-offs) improve near-surface resolution and extend service life.

Enquiry

Features

Typical Applications
  • Thickness Gauging
  • Plates
  • Bars & Pipes
  • Tanks

 

Key Benefits
  • Replaceable delay lines for extended transducer life
  • Can be used on higher temperature parts without damaging the transducer
  • Effective in small-flaw detection
  • Thickness Gauging on thin parts

 

Series


 
*HR Series – High Resolution series of transducers are highly damped and recommended for applications where enhanced axial and near-surface resolution are more important. Generally includes thickness measurement and near-surface flaw detection. HR series have less sensitivity and the GP or C series with -6db frequency bandwidth of 50-100% range.

Specifications

Part Numbers
Frequency (MHz) Element Diameter Part Number Delay 10-PK Delay 10-PK Accessories
inch mm HR* L=0.38 in (10 mm) L=0.50 in (12.7 mm)
2.25 0.25 6.4 00-010940 01-010810 01-010811
0.5 12.7 00-012301 01-011971 01-011973
3.5 0.25 6.4 00-010824 01-010810 01-010811 Cable
0.5 12.7 00-010941 01-011971 01-011973 MD – BNC
5 0.25 6.4 00-010246 01-010810 01-010811 6-ft (1.83 m)
0.5 12.7 00-010492 01-011971 01-011973 07-010012
10 0.25 6.4 00-010247 01-010810 01-010811
0.5 12.7 00-012302 01-011971 01-011973
15 0.25 6.4 00-011077 01-010810 01-010811

*HR = High Resolution; See Technology and Features tab for details.
 

Frequency (MHz) Element Diameter Part Number Delay 10-PK Accessories
inch mm HR* L=0.41 in (10.4 mm)
Nominal 20MHz 0.125 3.2 00-012300 01-011974 See above

*HR = High Resolution; See Technology and Features tab for details.
 
 

Case Dimensions
Element Diameter A B C
inch mm 0.38 in. Delay 0.50 in. Delay
0.125 3.2 0.50 in. 12.7 mm 0.83 in. 21.1 mm 0.95 in. 24.1 mm 0.30 in. 7.6 mm
0.25 6.4 0.50 in. 0.83 in. 21.1 mm 0.95 in. 24.1 mm 0.30 in. 7.6 mm
0.5 12.7 0.88 in. 22.4 mm 1.15 in. 29.2 mm 1.15 in. 29.2 mm 0.60 in. 15.2 mm
Mini-DFR
0.125 3.2 0.41 in. 10.4 mm 0.77 in. 19.6 mm 0.19 in. 4.8 mm

 

Downloads

Ultrasonic Transducers Catalogue

Engineering, Consultancy, and Solutions Provider
Malaysia
Vietnam
FOLLOW US
Malaysia
Vietnam
Engineering, Consultancy, and Solutions Provider

Copyright © – 2023 mitssolutions.asia