HD2010UC/A.Kit1: Class 1 Integrating Sound Level Meter and Analyzer


 

Integrating Class 1 Sound Level Meter with spectral or statistical analysis

HD2010UC/A has been designed either spectral or statistical analysis.
 
The instrument has been designed combining maximum usage flexibility, cost effective, and simplicity of use. The HD2010UC/A can be integrated with other options to extend its application scope at any time; the firmware can be updated directly by the user by means of the supplied NoiseStudio program.
 
The HD2010UC/A conforms to IEC 61672-1 of 2002 and IEC 61672-1 ed. 2.0 of 2013, IEC 60651 and IEC 60804 specifications with class 2 or class 1 tolerances. The constant percentage bandwidth (CPB) filters meet IEC 61620 class 1 specifications.
 
The kit includes Sound Level Meter HD2010UC/A Class 1, 1/2” UC52/1 pre-polarized condenser microphone, windscreen, preamplifier, USB or RS232 cable, carrying case, declaration of conformity, Noise Studio basic software version.
 
Available in Class 2 via model HD2010UC/A.kit2 – Class 2 Integrating Sound Level Meter and Analyzer

Enquiry

Features

  • Integrating portable sound level meter performing either spectral or statistical analysis.
  • Could be integrated with other options to extend its application scope at any time; the firmware can be updated directly by the user by means of the supplied Noise Studio program.
  • Conforms to IEC 61672-1 of 2002 and IEC 61672-1 ed. 2.0 of 2013, IEC 60651 and IEC 60804 specifications with class 2 or class 1 tolerances.
  • The constant percentage bandwidth (CPB) filters meet IEC 61620 class 1 specifications.
  • Possibility to log the noise time profile with parallel frequency weightings and time constants acquisition.
  • Automatically stores noise analysis of multiple acoustic descriptors as a data recorder, with a storing capacity of more than 23 hours at the maximum temporal resolution.
  • For long term noise monitoring, it’s possible to record together, with a time period from 1 s to 1h, 5 programmable parameters, the average spectrum and complete statistical analysis: with the “Memory module” option HD2010.O0 (it doubles the standard memory capacity), the HD2020UC/A can store, with a time interval of 1min, the noise multi-parameter and statistical analysis for more than 10 days.
  • Possibility to increase even further the memory capacity using the HD2010MC module.
  • This device is supplied with a 2GB SD memory card.
  • Offers a versatile trigger function for the noise event capture, with the additional possibility to filter false events; this is made verifying that the noise event level variation has a certain duration.
  • For each identified event, it’s possible to record 5 integrated parameters (user defined), average spectra in octave and third octave bands and the noise levels probability distribution sampled during the specific event.
  • Advanced functions of HD2010UC/A analyser, allow multi-parameters profile acquisition in parallel with reports sequences with dedicated parameters, average spectra and complete statistical analysis.
  • If an undesired sound event produces an over-load indication, or simply alters the result of an integration, its contribution can be excluded using the versatile Back-Erase function.
  • The impulsivity of a noise source is easily evaluated (according to criteria defined in UNI 9432 standard) measuring the A weighted equivalent sound pressure level with Impulse time constant (LAeqI).
  • The cyclic, fluctuating and impulsive noise sources identification is simple thanks to the powerful recording functions of HD2010UC/A analyser which allows, using a single measurement setup, to solve the most of situations encountered in working environments.
  • The HD2010UC/A sound level meter is suitable for sound level monitoring, acoustic mapping, and the assessment of the acoustic climate with capture and analysis of sound events.
  • When measuring traffic noise near airports, railways and roads, the sound level meter can be used as a multiparameter sound recorder, combining spectrum (option “Third octave” from 25Hz to 12.5KHz) and statistical analyser features.

Applications

  • Assessment and monitoring of the environmental noise level
  • Spectral analysis by octave bands from 31.5Hz to 8kHz
  • Optional (HD2010.O1) spectral analysis by third octave bands from 25Hz to 12.5kHz
  • Statistical analysis with percentile levels calculation from L1 to L99
  • Capture and analysis of sound events
  • Measurement at the workplace
  • Selection of personal protective equipment (SNR, HML and OBM methods)
  • Soundproofing and acoustic treatment
  • Production quality control
  • Measurement of machine noise
  • Optional architectural and building acoustics measurements.

Options

Third Octave

It adds a parallel bank of third octave filters from 25Hz to 12.5 kHz in class 1, according to IEC 61260. The filter bank works in parallel to all other measurements. The audibility of the different spectrum components can be evaluated applying A or C frequency weightings or thanks to the isophone (equal loudness level) curve calculation function of Noise Studio, a program supplied with the instrument.
 
 

Reverberation Time

Through this option the HD2010UC/A can carry out reverberation time measurements according to the techniques of the interruption of the sound source and of the impulsive source according to EN ISO 3382-2/2008 requirements. This measurement is made simultaneously for octave band from 125 Hz to 8 kHz and optionally for third octave band from 100 Hz to 10 kHz. The sampling interval equals 1/32s and the calculation of EDT, T10, T20 and T30 reverberation times is made automatically for all bands.

Downloads

HD2010UC/A.Kit1: Class 1 Integrating Sound Level Meter and Analyzer Manual
 
HD2010UC/A.Kit1: Class 1 Integrating Sound Level Meter and Analyzer Datasheet

Engineering, Consultancy, and Solutions Provider
Malaysia
Vietnam
FOLLOW US
Malaysia
Vietnam
Engineering, Consultancy, and Solutions Provider

Copyright © – 2023 mitssolutions.asia
Website Design Malaysia