HD32.3TC – HD32.3TCA: Thermal Microclimate PMV-PPD / WBGT


 
HD32.3TC and HD32.3TCA are Portable dataloggers suitable for indoor air quality and microclimate analysis (Indoor Air Quality, IAQ).
 
Thermal microclimate for the measurement of WBGT, PMV (mean predicted vote), PPD (predicted percentage of dissatisfied), DR (draught rate), TU (local turbulence intensity), HI (heat index), UTCI (Universal Thermal Climate Index), TEP (perceived equivalent temperature) indices, CO2, PM1.0, PM2.5 and PM10. Estimation of SARS-CoV-2 decay time on surfaces.
 
HD32.3TC is the portable version, mostly used in combination with a table stand (small tripod). HD32.3TCA is the version that is being used with a stable tripod, suitable to be used for measurements during a longer period.
 
Technically the difference is simple: with the HD32.3TCA the sensors are being connected by a cable and a black globe of 150mm is used. With the HD32.3TC the black globe is 50mm and the sensors are being connected directly on top of the instrument.
 
Both are fully according to the applicable ISO 7730, ISO 7726 and ISO 7243 regulations.

Enquiry
Category: Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Descriptions

HD32.3TC is a portable instrument indicated for the microclimate and Indoor Air Quality (IAQ) analysis.
 
Depending on the probes connected, the instrument measures:

  • T dry bulb temperature
  • Tnw natural ventilation wet bulb temperature
  • Tg globe thermometer temperature
  • RH relative humidity
  • Va air speed
  • CO2 carbon dioxide
  • Patm atmospheric pressure
  • PM1.0, PM2.5, PM10 particulate matter
  • VOC index (Volatile Organic Compounds)

and calculates:

  • WBGT indoor (Wet Bulb Globe Temperature) index in absence of solar irradiation
  • WBGT outdoor (Wet Bulb Globe Temperature) index in presence of solar irradiation
  • Mean radiant temperature Tr
  • PMV (Predicted Mean Vote) index
  • PPD (Predicted Percentage of Dissatisfied) index
  • TU (Turbolence) index
  • DR (Draft Rate) index
  • HI (Heat Index)
  • UTCI (Universal Thermal Climate Index)
  • TEP (Perceived Equivalent Temperature)
  • Estimation of SARS-CoV-2 virus natural decay on surfaces.

Reference standards:

  • ISO 7726 Ergonomics of the thermal environment – Instruments for measuring physical quantities.
  • ISO 7730 Ergonomics of the thermal environment – Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local
    thermal comfort criteria.
  • ISO 7243 Ergonomics of the thermal environment – Assessment of heat stress using the WBGT (wet bulb globe temperature) index.
  • ASHRAE Standard 55 Thermal Environmental Conditions for Human Occupancy.
  • ASHRAE Standard 62.1-2019 Ventilation for Acceptable Indoor Air Quality.
  • ASHRAE Standard 62.1-2019 Ventilation for Acceptable Indoor Air Quality.

Features

Instrument main features:

  • Data logger with large memory capacity for long measuring cycles.
  • Internal camera to store pictures of the monitored environment.
  • Rechargeable battery that guarantees an operating autonomy of at least 24 hours.
  • Backlit Colour 4” graphic LCD (active area 52×87 mm, 800×480 pixel) with capacitive touch.
  • Wi-Fi connection for sending the data to an FTP server.
  • Three inputs for probes with SICRAM module, which keeps memory of the probe calibration data. The probes can be inserted in any of the inputs: they are automatically recognized when the instrument is turned on.
  • RS485 serial port to which auxiliary probes can be connected: e.g., the probe for measuring Particulate Matter (PM).
  • OTG Mini-USB port for PC connection and battery charging.

A bright and clear touch display allows the calculated values for WBGT, PMV/PPD and TU to be directly visible. The data are immediately available via “cloud” application accessible remotely via Wi-Fi connection. The data logger has a large memory capacity for long lasting measurement cycles. Moreover, the rechargeable battery guarantees a working autonomy of at least 24 hours.

Applications

Microclimate applications:
  • In moderate environment (in compliance with ISO 7730 and ASHRAE 55 standards):
     
    – Measurement of the PMV, PPD and Tr global comfort indices.
    – Measurement of the DR local discomfort index.
     
  • In severe hot environment (in compliance with ISO 7243 standard):
     
    – Measurement of the WBGT index.
     

 

IAQ applications:
  • Measurement of comfort conditions and indoor air quality, for example in schools, offices, factories, etc.
  • Sick building syndrome analysis.
  • Verification of the efficiency of Heating, Ventilation and Air Conditioning (HVAC) systems.
  • Building Automation.

Downloads

HD32.3TC – HD32.3TCA: Thermal Microclimate PMV-PPD / WBGT Manual
 
HD32.3TC – HD32.3TCA: Thermal Microclimate PMV-PPD / WBGT Datasheet

Engineering, Consultancy, and Solutions Provider
Malaysia
Vietnam
FOLLOW US
Malaysia
Vietnam
Engineering, Consultancy, and Solutions Provider

Copyright © – 2023 mitssolutions.asia
Website Design Malaysia