HVAC40: HVAC Transmitters and Hygrostats


 
Transmitters and hygrostats series for measuring temperature, relative humidity and dew point in HVAC applications.
 
Over 40 years of experience in worldwide applications combined with a new design on accuracy, stability, simplicity and connectivity: this is the HVAC40 series.
 
These transmitters and hygrostats measure temperature, relative humidity and dew point using an interchangeable relative humidity and temperature digital sensor.
 
The probe is available in three different versions:

  • fixed vertical probe for wall mounting
  • fixed probe with 2 m cable
  • fixed duct horizontal probe

Available outputs, depending on the model:

  • RS485 Modbus–RTU digital output
  • 0…10 V voltage analog output
  • 0…20 mA / 4…20 mA active current analog output
  • 2-wire (current loop) 4…20 mA analog output
  • ON/OFF relay switch

Relay versions with settable alarm thresholds, hysteresis and delay and supplied as standard with LCD display. Optional LCD for all other versions.
 
The instruments are factory calibrated and ready for use.

Enquiry
Category: Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Descriptions

A stainless steel 10 μm filter protects the sensor against dust and particles (other filters are available for different applications).
 
The probe is available in three different versions:

  • fixed vertical probe for wall mounting (HVAC40…TV);
  • fixed probe with 2 m cable (HVAC40…TC.2);
  • fixed duct horizontal probe (HVAC40…TO).

Available outputs, depending on the model:

  • RS485 Modbus–RTU digital output (HVAC40S17…);
  • 0…10 V voltage analog output (HVAC40V17…);
  • 0…20 mA / 4…20 mA active current analog output (HVAC4017…);
  • 2-wire (current loop) 4…20 mA analog output (HVAC40A17…);
  • ON/OFF relay switch (HVAC40R17…).

Versions with 4-digit LCD display (option L) are available, which allow the measured parameters to be displayed. In the versions with LCD, two LED indicators indicate the presence of the power supply and of an eventual alarm condition: exceeding of the set measurements thresholds, in the versions with relay switch output; measurement detected outside the measuring range, in the versions with analog or digital output.
 
The configuration can be made by connecting the serial port of the instrument to the PC or by means of the quick configuration dip switches on the circuit board. The versions with relay switch output are equipped with two internal buttons for the configuration via display.

Downloads

HVAC40: HVAC Transmitters and Hygrostats Manual
 
HVAC40: HVAC Transmitters and Hygrostats Datasheet

Engineering, Consultancy, and Solutions Provider
Malaysia
Vietnam
FOLLOW US
Malaysia
Vietnam
Engineering, Consultancy, and Solutions Provider

Copyright © – 2023 mitssolutions.asia